3360305 - L26 ELECTRIC AIR PREHEATING IS NOT ACTIVATED WITH LOW EXTERNAL TEMPERATURE()
Outdoor temperature information is displayed correctly on the reconfigurable matrix.|  | The electrical preheating device
(present only on the JTD version) consists of two coils (PTC) of
different resistance ratings that generate a maximum power of 700 W
when current flows through them. the control unit is able to modulate
the heating by activing one coil or both. System activation is permitted only under the following conditions: 
 | 
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check the condition of the fuses specific to the air preheating system (electric): | Continue to Step 1 | Fuse blown | Replace the blown fuse | |
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Connect the Examiner and check for errors in the PTC device control relays | Continue to Step 2 | Relay damaged | Change the damaged relay | |
| 2 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Keep the Examiner connected and run active diagnosis on the two coils (PTC). | Continue to Step 5 | Mulfunctioning of both coils (PTC). | Continue to Step 3 | |
| 3 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
| Check that: 
 | Continue to Step 4 | electrical connectors incorrectly connected. | Connect the electrical connectors correctly. | |
| Electrical connection interrupted or not insulated. | Restore continuity/insulation of electrical connection See E6020 AIR CONDITIONING | |||
| Supply signal missing | Continue to Step 5 | |||
| 4 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | The fault persists | Change the coils (PTC) | |
| 5 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | The fault persists | Change the climate control node Op. 5040D18Search for the fault starting from another symptom' | |