3360172 - A32 ALARM DOES NOT GO OFF WITH BOOT RELEASE

The alarm system does not go off when boot opening is controlled via the remote control or mechanical key.
When in operational mode, the system disables the external volumetric/anti-tilt modules and the perimeter protection from the boot switch input when a boot lid opening control is received.
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect a tester to to the body computer node and check boot lid status (open or closed) has been properly received while in parameter mode.Continue to Step 4Boot lid status not received.Continue to Step 2
2CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check that the electrical connection between boot lid switch and body computer node is not broken or insulated.Continue to Step 3Electrical connection broken or not insulated. Restore continuity/insulation of the electrical connection between boot switch and body computer node. See   E7015  ALARM
3CHECKING COMPONENT OPERATIONAll OKProblems metOperation
Disconnect the connector on the body comuter node side and check for a boot open/closed signal. See   E7015  ALARM Continue to Step 4Boot electrical switch not working Change the boot catch Op. 7025B38
4CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsChange the body computer node Op. 5505A32Search for the fault starting from another symptom'