3360176 - B02 STARTER MOTOR NOT WORKING

The starter motor does not work when the igntiion is turned ON.
Results of the tests
0CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner) and check battery chargeContinue to Step 2battery charge insufficientRecharge the battery Op. 5530B10
battery charge insufficientReplace the battery Op. 5530B10
1CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of electrical connection between starter motor and battery See   E5010  STARTING AND RECHARING Continue to Step 2Electrical conection broken or not insulated.Restore continuity/insulation of electrical connection See   E5010  STARTING AND RECHARING
2CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of ignition barrel and starter motor connection. See   E5010  STARTING AND RECHARING Continue to Step 3Electrical connection broken or not insulated.Continue to Step 4
Check condition and correct operation of starter motor.Continue to Step 3Starter motor faulty.Overhaul the starter motor. ( Op. 5520B14)
Unrepairable starter motor faultReplace starter motor ( Op.   5520B12  )
3CHECKING IGNITION BARRELAll OKProblems metOperation
Check that the ignition barrel is working properly.Continue to Step 7Ignition barrel damaged.Change the ignition barrel Op. 5520A10.
4CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of electrical connection between ignition block and engine bay control unit See   E5010  STARTING AND RECHARING Continue to Step 5Electrical connection broken or not insulated.Restore continuity/insulation of electrical connection See   E5010  STARTING AND RECHARING
5CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of electrical connection between engine bay control unit and starter motor See   E5010  STARTING AND RECHARING Continue to Step 6Electrical connection broken or not insulated.Restore continuity/insulation of electrical connection See   E5010  STARTING AND RECHARING
6CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsChange the engine bay control unit Op. 5505A13.Search for the fault starting from another symptom'
7CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsChange theh engine bay control unit. Op.   5520B10  Search for the fault starting from another symptom'