3360297 - L02 CLIMATE CONTROL NOT WORKING / (NO AIR DELIVERY)

When the activation switch is pressed, the air conditioner system works correctly but no air comes out of any of the diffusers.
The climate control unit fan power supply is protected by specific fuses and controlled by a relay, housed in the engine bay control unit.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check the condition of the fan fan power supply fuses and relay.Continue to Step 1Fuses blownChange blown fuses
Relay damaged Change damaged relay
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect an Examiner and check fan motor operation via active diagnosis.Continue to Step 5Fan motor malfunctionContinue to Step 2
2CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check fan motor power supply See   E6020  AIR CONDITIONING Continue to Step 3No power supplyRestore continuity/insulation of the electrical connection between fan motor and fan control unit See   E6020  AIR CONDITIONING
3CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of the electrical connection between fan motor and climate control system node [wiring diagram E6020].Continue to Step 4Electrical connection interrupted or not insulated.Restore continuity/insulation of the electrical connection See   E6020  AIR CONDITIONING
4CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsChange fan motor Op.   5040C30 
5CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsChange the climate control system node Op. 5040D18Search for the fault starting from another symptom'