3360299 - L04 FAN' WILL NOT WORK AT DIFFERENT SPEEDS'

The fan motor does not work when the speed selector is used.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check the electrical connection is properly secured to the fan motor.)Continue to Step 1Electrical connection incorrectly connected.Connect the fan motor electrical connection correctly.
1CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of the electrical connection between the fan motor and climate control system node See   E6020  AIR CONDITIONING Continue to Step 2Electrical connection broken and not insulated.Restore electrical connection continuity/insulation. See   E6020  AIR CONDITIONING
2CHECKING SPEED SELECTORAll OKProblems metOperation
Check the speed selector is working properly. See Test   5040CC  Check fan motor speed selector operation Continue to Step 3Fan motor speed selector malfunctionChange the climate control system node Op. 5040D18
3CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsChange the fan motor Op.   5040C30  Search for the fault starting from another symptom'