3360301 - L12 CLIMATE CONTROL TOO COLD

The control button operates the passenger compartment air fan normally, but the temperature of the air is not correct.
Results of the tests
1CHECKING SYSTEM PRESSUREAll OKProblems metOperation
Connect the climate control system to the repressurizing equipment and check the system pressureContinue to Step 2System pressure incorrect.Restore correct system pressure. Op. 5040A10
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect an Examiner and check for errors:

  • in air mixing motors;
  • in treated air sensors;
  • in the frost sensor.
Continue to Step 4 Air mixing motor damagedContinue to Step 3
Treated air sensor damaged.Continue to Step 3
Frost sensor damaged.Continue to Step 3
3CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation

Check electrical connection continuity/insulation:

  • of air mixing motors
  • of treated air sensors;
  • of frost sensor.
Continue to Step 8Electrical connection interrupted or not insulated.Restore electrical connection continuity/insulation
4CHECKING PIPES AND FILTERAll OKProblems metOperation
Check high and low pressure pipes and air conditioning system filter are not blocked.Continue to Step 5Pipes from compressor to condenser blocked. Change the pipe from compressor to condenser Op. 5040A50
Pipes from compressor to condenser blocked. Change the pipe from condenser to filter Op. 5040A52
Pipes from compressor to condenser blocked. Change the pipe from filter to expansion valve Op. 5040S54
Pipes from compressor to condenser blocked. Replace the filter Op.   5040A44 
5CONDENSER CHECKAll OKProblems metOperation
Check that the condenser is not blocked.Continue to Step 6Condenser blockedReplace the condenser Op.   5040A40 
6EXPANSION VALVE CHECKAll OKProblems metOperation
Check that the expansion valve is working properlyContinue to Step 8Expansion valve not working properlyReplace the expansion valve Op. 5040B30
7CHECKING CORRECT OPERATION USING A TESTERAll OKProblems metOperation

Check errors do not persist:

  • in air mixing motors;
  • in treated air sensors;
  • in the frost sensor.
End of diagnosisAir mixing motor damagedChange mixed air motor (if LH) Op.   5040D84  Change mixed air motor (if RH) Op.   5040D86 
Air mixing motor damagedChange the treated air sensor Op. 5010D28
Air mixing motor damaged Change the frost sensor Op. 5040D22
8CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsChange the climate control node Op. 5040D18Search for the fault starting from another symptom'