3360303 - L16 CLIMATE CONTROL RECIRCULATION NOT WORKING

When the key on the switch panel is pressed, the
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner and check for errorsContinue to Step 2Air recirculation motor not workingContinue to Step 3
2CHECKING USING TESTERAll OKProblems metOperation
Keep the Examiner connected and check air recirculation motor operation by means of active diagnosisContinue to Step 7Air recirculation motor not workingContinue to Step 3
3CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of the electrical connection between the See   E6020  AIR CONDITIONING Continue to Step 4Electrical connection broken or not insulated.Restore electrical connection continuity/insulation
4RECIRCULATION MOTOR OPERATION CHECKAll OKProblems metOperation
Disconnect the electrical connector, air recirculation motor side, and check for a control signal from the climate control system node See   E6020  AIR CONDITIONING Continue to Step 5Signal absentContinue to Step 7
5CHECKING RECIRCULATION MOTOR FLAPAll OKProblems metOperation
Check that the air recirculation motor flap moves through its travel without sticking.Continue to Step 6Flap blocked or damagedRelease the air recirculation motor flap from its block or replace the flap if damaged.
6CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsChange the air recirculation motor Op. 5040D88
7CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsChange the climate control system node Op. 5040D18Search for the fault starting from another symptom'