3360310 - M05 MANUAL FRONT WINDOWS NOT WORKING

During the closure stage, the electric windows do not stop moving in the presence of obstacles
A sensor along the upper inside edge of the window stops the window in the presence of obstacles. The sensor is connected directly to the relevant door node and is always active, even with the key on STOP
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner) and check that there are no errors in the antipinch sensorContinue to Step 4Error found: antipinch sensor broken or signal missingContinue to Step 2
2CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of electrical connection between door Node and antipinch sensor See   E3050  ELECTRIC FRONT WINDOWS Continue to Step 3Electrical connection interrupted or not insulatedRestore electrical connection continuity/insulation See   E3050  ELECTRIC FRONT WINDOWS
3CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsChange the antipinch sensor Op.   7005D33 
4CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentThe fault persistsChange the damaged door Node Search for the fault starting from another symptom'