3362375 - 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE
|  | Follow the safety instructions ( Op. 5040 AIR CONDITIONING CASING AND COMPONENTS). | 

|  | For improved safety, the rapid attachment connectors for the equipment connection pipes have different diameters and are different colours: the one for the low pressure side is larger and blue and the one for the high pressure side is smaller and red. | 
|  | The fluid is extremely hygroscopic: avoid leaving the containers open. | 

|  | Type | Component | Name | Qty. | 
|---|---|---|---|---|
| - | Oil (cm) | Air conditioning system | - | - | 
|  | If the DENSO SCSB06 type compressor, fitted on the 1.2 16v version, is being replaced, do NOT carry out the procedure described above, but simply replace the old compressor with a new one without transferring fluid between the two compressors. | 
|  | Type | Component | Name | Qty. | 
|---|---|---|---|---|
| - | Fluid (g) | Air conditioning circuit | R134a | 500 ± 40 | 
|  | Use filtered air to prevent the introduction of foreign bodies into the system. | 
|  | If the system is being washed, the entire amount of fluid in the system is eliminated. | 
|  | Type | Component | Name | Qty. | 
|---|---|---|---|---|
| - | Oil (cm) | Air conditioning system | - | - |