3360335 - P41 DOORS DO NOT OPEN / VEHICLE WITH PASSIVE ENTRY
The automatic opening system does not work when the switch on the door handle is pressed.|  | The function is activated only with the car locked and allows the active door to be opened via CID recognition and all other doors to be released. The Passive Entry system strategy is managed by the passive entry Node, while the driver's door node, passenger door node and the boot node (if present) activate the door opening motors (electric locks). | 
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check CID battery charge status | Continue to Step 1 | battery charge insufficient. | Change CID battery | |
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Connect the examiner and check for errors: 
 | Continue to Step 3 | RF aerial damaged | Restore radio aerial continuity/insulation : | |
| Door aerial (one) damaged | Proceed to step 2 | |||
| 2 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
| Check continuity/insulation of the electrical connection between: 
 | Continue to Step 7 | Electrical connection broken or not insulated | Restore electrical connection continuity/insulation See E7018 PASSIVE ENTRY | |
| 3 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Keep the Examiner connected and check for errors in the door external handle switch. | Continue to Step 8 | No signal | Continue to Step 4 | |
| 4 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Check the exterior handle switch has been correctly downloaded while in parameter mode. | Continue to Step 8 | No signal | Continue to Step 5 | |
| 5 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
| Check continuity/insulation of the electrical connection between exterior handle and door catch. See E7018 PASSIVE ENTRY | Continue to Step 6 | Electrical connection broken or not insulated | Restore electrical connection continuity/insulation See E7018 PASSIVE ENTRY | |
| 6 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | The fault persists | If front door, change the exterior handle Op. 7005C11 | |
| The fault persists | If rear door, change the exterior handle Op. 7010C11 | |||
| 7 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | The fault persists | If front door aerial, change the defective aerial Op. 5580E72 | |
| The fault persists | If rear door aerial, change the defective aerial Op. 5580E74 | |||
| 8 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | The fault persists | Change the passive entry node Op. 5580E70 Search for the fault starting from another symptom' | ||