3360327 - O10 FRONT SEAT LUMBAR ADJUSTMENT NOT WORKING
When the switch is pressed the seat lumbar adjustment does not work.| Results of the tests | ||||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Connect the Examiner diagnostic equipment and check for the following at the CAN: 
 | Continue to Step 2 | Presence of faults. | Continue according to the instructions for the diagnostic equipment. | |
| 2 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Keep the Examiner diagnostic equipment connected and check for errors: 
 | Continue to Step 4 | Seat lumbar adjustment control switch error. | Continue to Step 8 | |
| Seat lumbar adjustment operating relay. | Continue to Step 3 | |||
| 3 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
| Check continuity/insulation of the electrical connection between the seat lumbar adjustment operating relay and the driver's position node/passenger position node See E3076 ELECTRICALLY-ADJUSTABLE SEATS . | Continue to Step 6 | Electrical connection interrupted or not insulated. | Restore electrical connection continuity/insulation See E3076 ELECTRICALLY-ADJUSTABLE SEATS . | |
| 4 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Check that the seat lumbar adjustment motor is working properly using active diagnosis. | Continue to Step 8 | Seat lumbar adjustment motor not working. | Continue to Step 5 | |
| 5 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
| Check continuity/insulation of the electrical connection between the seat lumbar adjustment motor and the driver's position node/passenger position node See E3076 ELECTRICALLY-ADJUSTABLE SEATS . | Continue to Step 8 | Electrical connection interrupted or not insulated. | Restore electrical connection continuity/insulation See E3076 ELECTRICALLY-ADJUSTABLE SEATS . | |
| 6 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Replace the seat lumbar adjustment operating relay. | |
| 7 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Replace the seat lumbar adjustment motor. | |
| 8 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Replace: 
 | |