3362987 - 5010D33 UPPER RIGHT MIXED AIR TEMPERATURE SENSOR - R.R.

Removing ( Refitting )  - 5530B56  BATTERY DRIP TRAY COVER - R.R.Disconnect the battery negative terminal. - 7040A45  facia rh side cover - r r - 7040A31  flap assembly - r r1. Disconnect the electrical connector for the right upper mixed air sensor.

NameConnector
1Upper treated air sensor  K88 
2. Release and remove the right upper mixed air sensor.
Refitting ( Removing ) Fit the right upper mixed air sensor in the special housing in the air conditioning casing.Connect the electrical connector for the right upper mixed air sensor.

NameConnector
-Upper treated air sensor  K88 
 - 7040A31  flap assembly - r r - 7040A45  facia rh side cover - r rConnect the battery negative terminal. - 5530B56  BATTERY DRIP TRAY COVER - R.R.