|  |  | Results of the tests | 
| 1 | CHECKING  WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|
|  | Connect
a tester to to the body computer node and check boot lid status
(open or closed) has been properly received while in parameter mode. | Continue to Step 4 | Boot lid status not received. | Continue to Step  2 | 
| 2 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
|---|
|  | Check
that the electrical connection between boot lid switch and body
computer node is not broken or insulated. | Continue to Step 3 | Electrical connection broken
or not insulated. | Restore continuity/insulation of the electrical
connection between boot switch and body computer node.   See   E7015  ALARM | 
| 3 | CHECKING COMPONENT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Disconnect
the connector on the body comuter node side and check for a boot
open/closed signal.   See   E7015  ALARM | Continue to Step 4 | Boot electrical switch
not working | Change the boot catch   Op. 7025B38 | 
| 4 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present | End of diagnosis | Fault persists | Change the body computer
node  Op. 5505A32Search for the fault starting
from another symptom' |