3362455 - 1040A70 submerged pump assembly complete with level guage control - r + r

Removing ( Refitting )  - 5530B56  BATTERY DRIP TRAY COVER - R.R.Disconnect the battery negative terminal. 1. Disconnect the fuel outlet and inlet pipes from the quick release fittings2. Use tool (2a) to unscrew lock collar (2b), then remove the fuel pump (2c) together with the level gauge.

NameCountry
2aKey1.870.736.000
Refitting ( Removing ) Place the fuel pump in the special housing in the tank.Fit the lock-nut and use the tool to tighten to torque.

NameCountry
-Key1.870.736.000
Replace the gasket under the fuel pump and take care, when refitting, to check that the gasket is correctly positioned in order to ensure the seal.
Connect the quick-release fittings for the fuel supply and return pipes.Connect the fuel pump and level gauge electrical connection.

NameConnector
-Fuel level gauge  N40 
Tighten the fuel pump protective cover retaining bolts.