3362992 - 5040A20 AIR CONDITIONING COMPRESSOR - R+R - INCLUDES FLUID LEVEL CHECK AND TOP UP IF NECESSARY

Removing ( Refitting ) Op. 5040A10 AIR CONDITIONING REFRIGERANT CIRCUIT - DRYING AND REPRESSURIZING1. Undo the fixing nut (1a) and disconnect the earth lead (1b).
DescriptionConnector
1bCompressor earth    C39
2. Undo the fixing bolts (2a) and disconnect the air conditioning system two high and low pressure pipes (2b) from the attachment on the compressor.3. Disconnect the electrical connection for the electro-magnet coupling.
DescriptionConnector
3Air conditioning compressor engagement electro-magnet    L20
Release the mounting bracket for the air conditioning system pipe from the compressor.
Raise the vehicle.    Op. 7055B54 UNDER ENGINE PROTECTION/GUARD - R.R.    Op. 4450B04 RIGHT FRONT WHEEL - R.R    7055B42 PASSARUOTA supplementare ANTERIORE (uno), sx o dx - S.R.    1092G10 CINGHIA unica comando organi motore - S.R.1. Undo the retaining bolts.2. Remove the air conditioning system compressor from the lower part of the engine compartment.
Refitting ( Removing ) Fit the air conditioning system compressor via the lower part of the engine compartment.Tighten the fixing bolts to torque.
FasteningComponentØ  Value(daNm)
-BoltAIR CONDITIONER ASSEMBLY COMPRESSORM10 X 1.25(Compressor support) 3.5
    1092G10 CINGHIA unica comando organi motore - S.R.    7055B42 PASSARUOTA supplementare ANTERIORE (uno), sx o dx - S.R.    Op. 4450B04 RIGHT FRONT WHEEL - R.R    Op. 7055B54 UNDER ENGINE PROTECTION/GUARD - R.R.Connect the electrical connection for the electro-magnet coupling.
DescriptionConnector
-Air conditioning compressor engagement electro-magnet    L20
Connect the air conditioning system two high pressure and low pressure pipes to the compressor.Tighten the bolts fixing the connectors to torque.Connect the earth lead and tighten the fixing nut.
DescriptionConnector
-Compressor earth    C39
FasteningComponentØ  Value(daNm)
-NutA/C ELECTRO MAGNETIC PULLEY ECU CABLE/SM8(Compressor) 1.5
Op. 5040A10 AIR CONDITIONING REFRIGERANT CIRCUIT - DRYING AND REPRESSURIZING