3362712 - 1080C24 e.g.r. system solenoid - r + r

Removing ( Refitting )  - 1016A10  sound-proofing cover - r + r . Disconnect the battery negative terminal.1. Disconnect the engine oil vapour recovery pipe from the engine oil filler.Release the engine oil vapour recovery pipe from the fastening band and move it sideways.
1. Undo the bolts fixing the exhaust gas outlet pipe from the water/exhaust gas heat exchanger for the E.G.R. system. 2. Disconnect the electrical connection from the E.G.R. valve.

NameConnector
2EGR solenoid  L30 
3. Undo the bolts fixing the E.G.R. system solenoid valve.4. Remove the E.G.R. system solenoid valve.Remove the gasket.
Refitting ( Removing ) Fit the E.G.R. system solenoid valve and gasket.Tighten the fixing bolts.Connect the electrical connection from the E.G.R. system solenoid.

NameConnector
-EGR solenoid  L30 
Screw in the bolts fixing the exhaust gas outlet pipe to the water/exhaust gas heat exchanger without tightening to torque.

FasteningComponentØValue(daNm)
-BoltENGINE OIL HEAT EXCHANGERM8 x 1.25(heat exchanger side 25
Secure the engine oil vapour recovery pipe to the bands and fasten it using the band.Connect the battery negative terminal. - 1016A10  sound-proofing cover - r + r