3363017 - 5040C93 LEFT SIDE VENTILATION DISTRIBUTION FLAPS - R.R. WITH AIR CONDITIONING CASING REMOVED

Removing ( Refitting ) 1. Disconnect the electrical connectors for the distribution flap (1a) and left upper mixed air sensor (1b) motors

NameConnector
1aAir distribution actuator  N80 

NameConnector
1bUpper treated air sensor  K88 
Undo the motor mounting fixing bolts.2. Remove the mounting and motors.
1. Remove the drive gears from the flap shafts.2. Undo the bolts fixing the sealing plug in the flap housing.Remove the sealning plug for the housing for the flaps and the left distribution - vent flaps.
Refitting ( Removing ) Fit the distribution - vent flaps in their housings.Position and secure the sealing plug in the flap housing tightening the fixing bolts.Fasten the flap drive gears.Secure the distribution motors support tightening the fixing bolts.Connect the electrical connectors for the distribution flap and left upper mixed air sensor motors.

NameConnector
-Air distribution actuator  N80 

NameConnector
-Upper treated air sensor  K88