3360205 - D02 ENGINE NOT RUNNING SMOOTHLY / (LOSING POWER)

Under conditions of constant load and speed, there are intermittent decreases in performance, even prolonged
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation

First check:

  • the condition of the air filter;
  • the condition of the air intake circuit
Continue to Step 1Blocked filterReplace the filter element Op.   1048A14 
Blocked filterEliminate the problem
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket.

Verify:

  • that there are no faults in the engine management control unit
  • the plausibiilty of the parameters
Continue to Step 2'Fuel system' error appears See table   Z50  MIXTURE STRENGTH ERROR
'Misfiring' error appears See table   Z53  MISFIRE ERROR
Incoherent parameterContinue following the instructions for the diagnostic equipment
Incoherent parameterContinue following the instructions for the diagnostic equipment
2ROAD TEST WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Road test the vehicle, reproducing the conditions in which the fault arises, keeping the diagnostic equipment connected.

Verify:

  • that there are no faults in the engine management control unit
  • the plausibiilty of the parameters
Continue to Step 3'Fuel system' error appears See table   Z50  MIXTURE STRENGTH ERROR
Incoherent parameters See table   Z53  MISFIRE ERROR
Incoherent parametersContinue following the instructions for the diagnostic equipment
Incoherent parametersContinue following the instructions for the diagnostic equipment
3FUEL PRESSURE ROAD TESTAll OKProblems metOperation
Road test the vehicle and check the fuel supply pressure in the conditions that lead to the anomaly Op. 0510C10Continue to Step 4Insufficient fuel presure: pipes obstructedRemove the blockages and replace the pipes if necessary
Insufficient fuel pump: pump faultyReplace the fuel pump assembly Op.   1040A70 
4CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persists: control unit defectiveReplace control unit Op.   1056B82  Search for the fault starting from another symptom'