3360286 - K90 INSTRUMENT LIGHTS / NOT WORKING

With the ignition ON, the display does not display the time correctly or at all.
The interior lighting signal is sent from the body computer node via the B-CAN network to the instrument panel node
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the diagnostic equipment (Examiner or other instruments) and check CAN network information for

  • control units inactive
  • control unit errors
  • control units with errors in CAN line
Continue to Step 2Presence of faults Continue following the instructions for the diagnostic equipment
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Keep the diagnostic equipment (Examiner or other instruments) connected to the tester input and check the instrument panel node for:

  • panel lighting function via active diagnosis
Continue to Step 3Instrument panel does not light upReplace instrument panel Op. 5560B11
3CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsReplace the Body Computer Op. 5505A32Search for the fault starting from another symptom'