3360288 - K95 WARNING LIGHT SYMBOLS DO NOT COME ON / (IN INSTRUMENT PANEL)

The instrument panel is completely off.
Results of the tests
1PRELIMINARY CHECKAll OKProblems metOperation
Connect an Examiner to the diagnostic socket

Verify:

  • Control panel is properly supplied with power
Continue to Step 2+15- +30 power supply incorrectRestore power supply: wiring diagram See   E4010  INSTRUMENT PANEL
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the tester to the tester input and check:

  • the operation of the instrument panel in active diagnosis;
Continue to Step 3Instrument panel not workingReplace instrument panel Op. 5560B11
3CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'