3360302 - L15 CLIMATE CONTROL NOT HEATING

Climate control system recirculation does not work in every state (normal/automatic)
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner) to the diagnostic socket.Check that there are no faults in the climate control system control unitContinue to Step 2An error is detected in the control unitContinue following the instructions for the diagnostic equipment
Lack of dialogue with the control unitRestore connection between climate control system control unit and body computer: See   E6020  AIR CONDITIONING
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the diagnostic equipment (Examiner or other instruments) carry out active diagnosis on the recirculation motorContinue to Step 3Recirculation motor connection faultyRestore the correct connection See   E6020  AIR CONDITIONING
Recirculation motor faultyReplace the recirculation motor Op.   5040D52 
Recirculation motor flap faultyReplace the recirculation motor flap Op.   5040D52 
3HECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'