3360309 - M03 ONE OF THE ELECTRIC FRONT WINDOWS IS NOT WORKING

When the appropriate switch is pressed, one of the front electric windows, left or right, does not work properly.
The window electrical motor is controlled directly by the relevant door node, which receives a window open/close command from a switch on the door panel. The door node supply is protected by a special fuse housed in the underfacia junction unit, and controlled by a relay which is also housed in the underfacia junction unit
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check the condition of the protective fuse See   E3050  ELECTRIC FRONT WINDOWS Continue to Step 1Fuse blownReplace blown fuse
1PRELIMINARY CHECKAll OKProblems metOperation
Check that there are no obstacles preventing the travel of the windowAlso check that the window is secured properly to the window electric motorContinue to Step 2Presence of obstaclesRemove the obstacle
Window incorrectly fixed to the electric window motorSecure the window to the electric window motor correctly
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect an Examiner and check for errors on the B-CAN line.Check switches on the door panel have been properly downloaded while in parameter modeContinue to Step 3Errors in B-CAN lineContinue according to the instructions for the diagnostic equipment.
Switch on door panel not workingContinue to Step 5
3CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check the door Node is correctly supplied See   E3050  ELECTRIC FRONT WINDOWS Continue to Step 4Door node not correctly supplied: absence of power suppy or earthRestore electrical connection of door node power supply or earth
4CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Connect continuity/inslation of the electrical connection between doro Node and electric window motor. See   E3050  ELECTRIC FRONT WINDOWS Continue to Step 5Electrical connection broken or not insulatedRestore continuity/insulation of the electrical connection
5CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check the correct power supply from the door node to the electric window motor See   E3050  ELECTRIC FRONT WINDOWS Continue to Step 8Supply to electric motor missingChange the damaged door node
6CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of the electrical connection between door node and switch panel on door See   E3050  ELECTRIC FRONT WINDOWS Continue to Step 7Electrical connection broken or not insulatedRestore continuity/insulation of the electrical connection See   E3050  ELECTRIC FRONT WINDOWS
7CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsReplace the switch panel on the door Op. 7005M11
8CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsChange the switch panel on the door Op.   7005M21  Search for the fault starting from another symptom'