3360334 - P40 AUTOCLOSE NOT WORKING / VEHICLE WITH PASSIVE ENTRY

The autoclose system does not work when the driver closes the door and walks away from the car.
The autoclose function can be selected from the instrument panel node nad allows the CID owner to lock the door catch automatically when he or she moves away from the car.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check that the autoclose function activates via the instrument panel node.Continue to Step 1Function deactivatedActivate the function via the instrument panel node
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect an Examiner and check the door open/close signal has been correctly downloaded while in parameter mode. Carry out the check on each individual door.Continue to Step 3Door open/close signal missingContinue to Step 2
2CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of electrical connection between body computer node and door lock See   E7018  PASSIVE ENTRY Continue to Step 6Electrical connection interrupted or not insulatedRestore continuity/insulation of electrical connection See   E7018  PASSIVE ENTRY
3CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keep the Examiner connected and check for errors in the passive entry aerials on the doors Continue to Step 7Error found in one door aerialContinue to Step 4
4CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation
Check continuity/insulation of electrical connection between aerial and passive entry nodeContinue to Step 5Electrical connection interrupted or not insulatedRestore continuity/insulation of electrical connection See   E7018  PASSIVE ENTRY
5CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsReplace front door passive entry aerial Op.   5580E72 
The fault persistsReplace rear door passive entry aerial Op.   5580E74 
6CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsChange the defective front door catch Op. 7021N72
The fault persistsChange the defective rear door catch Op.   7010N21 
7CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentThe fault persistsChange the passive entry node Op.   5580E70  Search for the fault starting from another symptom'