|  |  | Results of the tests | 
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation | 
|---|
|  | Approach
the car, press the switch on the exterior handle of another door
and check the passive entry system works correctly. | Continue to Step 1 | The fault persists | Continue as instructed in
the diagnostic table See table   P40  AUTOCLOSE NOT WORKING | 
| 1 | CHECKING  WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|
|  | Connect
an Examiner and check that there are no errors in the defective
door aerial on the passive entry node. | Continue to Step 3 | Door aerial defective | Continue to Step  2 | 
| 2 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
|---|
|  | Check
continuity/insulation of the electrical connection between the door
aerial and passive entry node.  See   E7018  PASSIVE ENTRY | Continue to Step 7 | Electrical connection broken
or not insulated | Restore electrical connection continuity/insulation  See   E7018  PASSIVE ENTRY | 
| 3 | CHECKING  WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|
|  | Keep
the Examiner connected and check door exterior handle switch status
has been correctly downloaded while body computer node is in parameter
mode. | Continue to Step 8 | Door exterior handle switch status
signal missing | Continue to Step  4 | 
| 4 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
|---|
|  | Check
continuity/insulation of the electrical connection between the door
exterior handle and passive entry node  See   E7018  PASSIVE ENTRY | Continue to Step 5 | Electrical connection broken
or not insulated | Restore electrical connection continuity/insulation  See   E7018  PASSIVE ENTRY | 
| 5 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
|---|
|  | Check
continuity/insulation of the electrical connection between the exterior
handle and the relevant door node   See   E7018  PASSIVE ENTRY | Continue to Step 6 | Electrical connection broken
or not insulated | Restore electrical connection continuity/insulation
  See   E7018  PASSIVE ENTRY | 
| 6 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present | End of diagnosis | The fault persists | If front door, change the
exterior handle of the defective door  Op.   7005C11 | 
| The fault persists | If rear door, change the exterior handle of the defective
door  Op.   7010C11 | 
| 7 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present | End of diagnosis | The fault persists | If front door, change the
defective door aerial  Op.   5580E72 | 
| The fault persists | If rear door, change the defective door aerial  Op.   5580E74 | 
| 8 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present |  | The fault persists | Change the passive entry
node Op.   5580E70   Search for the fault starting
from another symptom' |