3360175 - B01 IGNITION SWITCH NOT WORKING
When the ignition is turned ON nothing happens. The starter motor does not turn and none of the appliances connected to the ignition barrel work.| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check the condition of the fuse See E5010 STARTING AND RECHARING | Continue to Step 1 | Fuse blown | Change the blown fuse See E5010 STARTING AND RECHARING | |
| Battery discharged and no longer rechargeable | Replace battery ( Op. 5530B10) | |||
| 1 | CHECKING BATTERY | All OK | Problems met | Operation | 
| Check battery charge | Continue to Step 2 | Battery charge insufficient | Recharge the battery Op. 5530B10 | |
| Battery flat and no longer rechargeable | Replace the battery Op. 5530B10 | |||
| 2 | CHECKING BATTERY | All OK | Problems met | Operation | 
| Check, in order: 
 | Continue to Step 3 | Connections not correct | Renew the electrical connections | |
| Damaged earth lead terminal | Change the battery earth lead Op. 5530B22) | |||
| 3 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
| Check the continuity/insulation of the electrical connection between the battery and the engine bay control unit See E5010 STARTING AND RECHARING | Continue to Step 4 | Electrical connection broken or not insulated. | Restore continuity/insulation of electrical connection See E5010 STARTING AND RECHARING ) | |
| 4 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation | 
| Check continuity/insulation of electrical connection between the engine bay control unit and ignition barrel. | Continue to Step 5 | Electrical connection broken or not insulated. | Restore continuity/insulation of electrical connection See E5010 STARTING AND RECHARING | |
| 5 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change the ignition barrel Op. 5520A10.Search for the fault starting from another symptom' | |