3360210 - D21 ENGINE CUTS OUT WHILST DRIVING
The engine cuts out suddenly whilst driving. Later, after starting normally, it works again| Results of the tests | ||||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation | ||
|---|---|---|---|---|---|---|
| First check: 
 | Continue to Step 1 | Earth lead incorrectly fastened | Renew or, if necessary, replace the battery earth lead Op. 5530B22 | |||
| Battery postive incorrectly fastened | Restore battery positive lead Op. 5530B26 | |||||
| Presence of water in the fuel | Replace the fuel | |||||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | ||
| Connect
the diagnostic equipment (Examiner or other instruments) to the
diagnostic socket. Verify: 
 | Continue to Step 2 | Error detected in the control unit | Continue following the instructions for the diagnostic equipment | |||
| Incoherent parameter | Continue following the instructions for the diagnostic equipment | |||||
| 2 | ROAD TEST WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | ||
| Road
test the vehicle, reproducing the conditions in which the fault
arises, keeping the diagnostic equipment connected. Verify: 
 | Continue to Step 3 | Error arises suddenly in the control unit | Continue according to the instructions for the diagnostic equipment | |||
| Incoherent parameter | Continue according to the instructions for the diagnostic equipment | |||||
| Loss of communication between the control unit and diagnostic instrument | Restore the control unit circuit supply See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | |||||
| 3 | FUEL PRESSURE ROAD TEST | All OK | Problems met | Operation | ||
| Road
test the vehicle and check the fuel supply pressure Op. 0510C10 
 | Continue to Step 4 | Pressure not correct: obstructions in the pipe | Remove the obstructions in the fuel pipe, and if necessary replace it | |||
| Pressure incorrect: fuel pump damaged | Replace fuel pump assembly Op. 1040A70 | |||||
| 4 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | ||
| Check that the fault is no longer present | Fault persists: control unit defective | Replace control unit Op. 1056B82 Search for the fault starting from another symptom' | ||||