|  |  | Results of the tests | 
| 1 | CHECKING ELECTRICAL EQUIPMENT | All OK | Problems met | Operation | 
|---|
|  | Check
the condition of the wiring between the body computer node and affected
light.  See   E2010  SIDE LIGHTS / NO. PLATE LIGHTS | Continue to Step 2 | Wiring short circuited
or with circuit open | Renew the electrical connections  See   E2010  SIDE LIGHTS / NO. PLATE LIGHTS | 
| 2 | CHECKING LIGHT ELECTRICAL SYSTEM | All OK | Problems met | Operation | 
|---|
|  | Check
internal light connections  See   E2010  SIDE LIGHTS / NO. PLATE LIGHTS | Continue to Step 3 | Connections short-circuited | Restore to operation and
change light if necessary | 
| 3 | CHECKING BUILB CONDITION | All OK | Problems met | Operation | 
|---|
|  | Check
the condition of both bulbs | Continue to Step 4 | Bulbs faulty | Replace bulbs | 
| 4 | CHECK CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present |  | Light does not come on | Replace the Body Computer  Op. 5505A32Search
for the fault starting from another symptom' |