3360265 - K01 REV COUNTER NOT WORKING
With the engine started, the rev counter does not work, or it works irregularly.|  | The rpm signal supplied by the 'engine management node' and via the 'Body Computer node' gateway is made available to the 'instrument panel node' | 
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check that with the engine started up: 
 | Continue to Step 2 | There are faults detected | Continue to Step 1 | |
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Connect
the diagnostic equipment (Examiner) to the body computer Check the following on the CAN information network: 
 | Continue to Step 2 | Presence of errors at instrument panel node | Continue according to the instructions for the diagnostic equipment | |
| Presence of errors at instrument panel node | Continue to Step 2 | |||
| 2 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Connect the diagnostic equipment (Examiner) to the diagnostic socket or keep it connected and check: 
 | Continue to Step 3 | For the presence of errors or failed dialogue with the diagnostic equipment | Continue according to the instructions for the diagnostic equipment | |
| 3 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Keeping the diagnostic equipment (Examiner) connected to the diagnostic socket, check: 
 | Continue to Step 4 | Rev counter is not working | Replace instrument panel Op. 5560B11 | |
| 4 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | The fault persists | Search for the fault starting from another symptom' | ||