3360273 - K26 ENGINE COOLANT OVERHEATING WARNING LIGHT NOT WORKING
|  | the warning light on signal is made available by the 'engine management node' at the C-CAN network; the 'body computer node' makes the message available via the gateway to the B-CAN network and then to the instrument panel; | 
| Results of the tests | ||||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket and check at the instrument panel node: 
 | Continue to Step 2 | Warning light not working | Replace instrument panel Op. 5560B11 | |
| 2 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| 1.2 16v | Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check at the engine management node: 
 | Continue to Step 3 | Indicator not working | Replace the engine control unit Op. 1056B82 | 
| 1.6 16v | Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check at the engine management node: 
 | Continue to Step 3 | Indicator not working | Replace the engine control unit Op. 1056B82 | 
| 1.8 16v | Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check at the engine management node: 
 | Continue to Step 3 | Indicator not working | Replace the engine control unit Op. 1056B82 | 
| 2.4 20v | Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check at the engine management node: 
 | Continue to Step 3 | Indicator not working | Replace the engine control unit Op. 1056B82 | 
| 1.2 16v 1.6 16v 1.8 16v 1.9 JTD 8v | Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check at the engine management node: 
 | Continue to Step 3 | Indicator not working | Replace the engine control unit Op. 1060G80 | 
| 3 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | Fault persists | Search for the fault starting from another symptom' | ||