3360358 - Z57 UPSTREAM LAMBDA SENSOR SIGNAL ERROR
The diagnostic equipment signals the following error: Upstream Lambda signal (slow)| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Connect the tester (Examiner or Examiner Plus) and transcribe the errors and environmental parametersCheck for the 'Upstream Lambda signal (slow)' error only | End of diagnosis | 'Upstream lambda probe' error present | See table Z56 | |
| Only the 'Upstream Lambda signal (slow)', 'Mixture strength', 'Misfire', 'Catalyzer' and/or 'Downstream Lambda signal' errors are present | Continue to Step 1 | |||
| Other errors present | Identify and eliminate the cause of the anomaly.Continue to Step 3 | |||
| 1 | SENSOR CHECK | All OK | Problems met | Operation | 
| Visually inspect: 
 | Continue to Step 2 | Wiring faulty | Fit the Lambda sensor correctly Op. 1080B60 Continue to Step 3 | |
| Wiring faulty | Replace faulty componentsContinue to Step 3 | |||
| Wiring faulty | Restore correct connections. If necessary, replace the faulty components See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT Continue to Step 3 | |||
| 2 | REPLACING UPSTREAM LAMBDA SENSOR | All OK | Problems met | Operation | 
| Replace
the upstream Lambda sensor  Op.   1080B60   Search for the cause of the pollution in the sensor. The probable causes are: 
 | Continue to Step 3 | Use of contaminated petrol | Clean the tank Op. 1040A24and introduce suitable quality fuel.Continue to Step 3 | |
| Engine oil leaks detected | See table X12 | |||
| 3 | DELETING AND CHECKING ERROR | All OK | Problems met | Operation | 
| Use a tester to cancel the errors in the control unit.Carry out a road test and ensure the error does not recur | Continue to Step 4 | The fault persists, but it is the second time that this step has been reached or the Lambda sensor has already been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached or the Lambda sensor has already been replaced | Contact Technical Support for further information on the problem | |||
| 4 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | |||