3360383 - Z83 SUPPLY VOLTAGE ERROR
The diagnostic equipment signals the following error: C1802 Supply voltage|  | This error is signalled if the control unit detects battery voltage that is either too high or too low. | 
| Results of the tests | ||||
| 1 | SUPPLY CIRCUIT CHECK | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check that the supply voltage at the battery terminals is correct.Check the supply wiring from the battery to the ABS control unit See E7020 ABS : there should not be a drop in voltage between the battery and the control unit | End of diagnosis | Battery voltage incorrect | Recharge the battery, if necessary, replace it. Op. 5530B10 | |
| Fall in wiring voltage | Renew the wiring, if necessary, replace the faulty components | |||
| 2 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation | 
| Delete the errors using the diagnostic equipment.Carry out road See Test 3340A ABS intervention check to make the control unit check whether there are still errors present. Return to the workshop and check that the fault is no longer present using the diagnostic equipment. | End of diagnosis | . | ||