3362997 - 5040A60 pipe from condenser to evaporator (expansion pipe) - r+r
Removing ( Refitting ) - 5040A10 Air conditioning refrigerant CIRCUIT - Draining and Refilling - 7055B54 under-engine guard - r r - 7055B42 Additional FRONT WHEEL ARCH (one), left or right - R.R. (Right). 1. Undo the nut (1a) and disconnect the connector (1b) from the expansion valve (1c).
1. Undo the nut (1a), open the retaining bands (1b) and move the
mounting bracket and the petrol pipes (1c) aside.2. Open the band (2a) retaining the pipe from the compressor to
the condenser (2b).
Loosen the bolt and release the bracket
anchoring the pipe to the strut.1. Loosen the nut (1a), disconnect the connector (1b) and remove
the pipe (1c) from the expansion valve to the condenser.
Refitting
(
Removing
)
Position the pipe from the expansion valve
to the condenser.Position the connector on the expansion
valve and secure it using the special nut.Position the connector on the condenser
and secure it using the nut. - 7055B42 Additional FRONT WHEEL ARCH (one), left or right
- R.R.
(Right)
- 7055B54 under-engine guard - r r- 5040A10 Air conditioning refrigerant CIRCUIT - Draining and
Refilling