3363028 - 5040D63 AIR DISTRIBUTION FLAP CONTROL ACTUATORS - R.R. WITH AIR CONDITIONING CASING REMOVED

Removing ( Refitting ) 1. Disconnect the electrical connectors (1a) of the defrost actuator and the connector (1b) of the ventilation distribution actuator.

NameConnector
1aAir distribution - defrost flap actuator  N83 

NameConnector
1bAir distribution actuator  N80 
2. Undo the bolts fixing the actuator mounting bracket.3. Remove the bracket with the actuators.Separate the actuators from the mounting bracket.4. Remove the transmission gears of the air distribution flap actuators.
Refitting ( Removing ) Fit the gears on the respective spindles of the air distribution flaps.Fit the actuators on the mounting bracket.Secure the mounting bracket with the actuators to the climate control casing, tightening the fixing bolts.Connect the electrical connectors (1a) of the defrost actuator and connector (1b) of the ventilation distribution actuator.

NameConnector
-Air distribution - defrost flap actuator  N83 

NameConnector
-Air distribution actuator  N80