3363036 - 5040D87 RIGHT AIR CONDITIONING MIXTURE FLAP CONTROL MOTOR - R.R. WITH AIR CONDITIONING CASING REMOVED

Removing ( Refitting ) 1. Unscrew the motor retaining bolt.2. Disconnect the motor electrical connector.

NameConnector
1bRight air mixture flap actuator  N79 
3. Remove the motor controlling the right air mixing flap.4. Prise off and remove the transmission linkage for the right air mixing motor.
Refitting ( Removing ) Fit in its seating the transmission linkage for the right air mixing motor.
Be careful with the centring dowel.
Fit the motor controlling the right air mixing flap and tighten the fixing bolts.Connect the motor's electrical connector.

NameConnector
-Right air mixture flap actuator  N79