194002028 - N065 CONNECT NOT WORKING

The Connect screen does not come on (goes on and off sporadically)
0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
Check the Connect system comes on with key onCheck the Connect system comes on when the On/Off key is pressedEnd of diagnosis1.Will not come on with the key on1.Continue to step 1
2.Will not come on when the button is pressed2.Continue to step 1
1ELECTRICAL CONNECTION CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Withdraw the Connect from the dashboard.

  • Check connections and wiring continuity

  • Check the condition of the fuse on the Connect body.

  • Check that the correct power supplies are present at the Connect connectors
    See Test 5580PO CHECK ON CONNECT POWER SUPPLY
Move on to Step 21.Wiring interrupted1. Renew the blown fuse after ascertaining the cause
2.No power2. Restore correct power supply    See E4090 NAVIGATOR
3. Incorrect earth connection3. Restore the correct earth connection    See E4090 NAVIGATOR
2CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that it is working properlyEnd of diagnosisThe fault persistsReplace Connect    Op. 5580P12 CONNECT PANEL REPLACE