194002475 - K038 MILOMETER/TRIP METER FLASHING

At the end of the lights check the panel milometer/trip meter starts to flash
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment and check in the "Control Units Test" ambient, "Other Systems" Assembly, "Proxi Alignment Procedure" Systems, that the "Instrument Panel Node" alignment has taken placeMove on to Step 81. Impossible to carry out Proxi alignment1. Move on to Step 2
2. Alignment not carried out2. Carry out Proxi alignment
2INSTRUMENT PANEL CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the panel installed is correct for the vehicle trim level (a panel for a petrol version cannot be fitted on a diesel version)Move on to Step 3Panel does not correspond with the vehicle trim levelReplace instrument panel    Op. 5560B10 CONTROL PANEL - R+R
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment and check, in the Instrument Panel Node ambient, that there are no errors and that the parameters are presentMove on to Step 81. Connection with NQS impossible1. Move on to Step 4
2. Presence of errors2. Move on to Step 7
4ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the electrical power supply for the "Instrument Panel Node" is correct    See E4010 INSTRUMENT PANELMove on to Step 5Positive and/or earth electrical power supply faultyRenew and/or replace the defective component (in the case of a fuse, find out what caused it to blow).
5ELECTRICAL CONNECTIONS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the wiring/electrical connections for the Instrument Panel Node, in particular that every pin is correctly connected and fitted in placeMove on to Step 6Wiring and/or electrical connections not workingRestore the wiring and/or damaged electrical connections
6CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner, check the possibility of connecting with the Instrument Panel NodeMove on to Step 7Impossible to connect with the control unitReplace instrument panel    Op. 5560B10 CONTROL PANEL - R+R
7CHECK ERRORSALL OKPROBLEMS ENCOUNTEREDACTION
Check for the presence of one or more of the following errors using the Examiner in the Instrument Panel Node ambient:

  • CAN line

  • EEPROM
Move on to Step 81. "No additional information" and/or "BUS off" detected1. Continue as described by the diagnostic equipment
2. EEPROM faulty2. Replace instrument panel    Op. 5560B10 CONTROL PANEL - R+R
8ACTIVE DIAGNOSIS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check, using the Examiner in active diagnosis that the autotest function is correctly activatedMove on to Step 9The function in question is not controlled by the active diagnosisReplace instrument panel    Op. 5560B10 CONTROL PANEL - R+R
9CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer present.End of diagnosis