194002476 - K040 BATTERY CHARGING WARNING LIGHT NOT WORKING

when the key is turned on the recharging warning light does not come on
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner equipment to the diagnostic socket.Check warning light operation in active diagnosis modeMove on to Step 2Warning light does not come onReplace the instrument panel    Op. 5560B10 CONTROL PANEL - R+R
2ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the body computer power supplies are correct and in particular the "D+" signal by carrying out    See Test 5530AA CHECK ON ALTERANTOR D+ TERMINAL VOLTAGEMove on to Step 31.Body Computer power supply not correct1.Restore correct power supplies
2.D+ signal between alternator and Body Computer interrupted due to defective wiring2.Renew the wiring
3.Alternator defective3.Replace alternator    Op. 5530A10 ALTERNATOR - R+R
3CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosis