194002838 - K146 ONE WARNING LIGHT OPERATED BY CONTROL PANEL ON CONSTANTLY

When the lights/heated rear windscreen are deactivated from the control panel, the warning light in the instrument panel does not go out N.B: The warning lights activated from the panel are:

  • Foglamps (left control panel)
  • Rear foglamps (left control panel)
  • Hazard warning lights (control panel on centre tunnel)
  • Heated rearscreen (climate control panel)
0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
With the ignition OFF, activate the hazard warning lights and switch them off and check that they come on/go out.With the ignition ON, activate all the functions in question using the left control panel and switch them off, namely:

  • fog lights

  • rear fog lamps

  • heated rear windscreen and check that they are activated/deactivated
Move on to Step 11. The hazard lights do not work1. Continue as described by the diagnostic equipment
2. The foglamps are not working2. Continue as described by the diagnostic equipment
3. The rear foglamps are not working3. Continue as described by the diagnostic equipment
4. The heated rearscreen4. Continue as instructed in the    See table J021 HEATED REAR WINDSCREEN NOT WORKING
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner diagnostic equipment check, in Instrument Panel mode, that there are no errors and that the parameters are present.Move on to Step 2Presence of errorsContinue following the instructions on the diagnostic instrument
2ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electricity supply to the Instrument Panel Node is correct.Move on to Step 3Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
3CHECK ELECTRICAL CONNECTIONSALL OKPROBLEMS ENCOUNTEREDACTION
Check the electrical connections between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected.Move on to Step 4Electrical connections not operationalRenew the damaged electrical connections
4ACTIVE DIAGNOSIS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
With the Examiner in Instrument Panel Node mode, check that the warning lights in question are correctly activated in Active Diagnosis.Move on to Step 5The warning lights do not flashReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
5CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner check, in the Body Computer Node mode, that there are no errors and that the parameters are present.Move on to Step 61. Impossible to connect to the Body Computer control unit.1. Move on to Step 6
2. Presence of errors.2. Continue following the instructions on the diagnostic instrument
3. The parameters do not change3. Move on to Step 8
6ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electricity supply to the Body Computer Node is correct.Move on to Step 7Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
7CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Use an Examiner to check the possibility of connection to the Body Computer NodeMove on to Step 8Impossible to connect to the Body Computer control unit.Replace Body Computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.
8CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosis