194002892 - Y052 P0651 - POWER SUPPLY TO SENSORS 2

The diagnostic equipment signals: Error P0651 (Sensor power supply 2).
This error is detected if there is a short circuit to positive (detail "beyond the upper limit") or a short circuit to earth or a brek (detail "below the lower limit") in the circuit connected to Pin 46, 13 or 28 of the junction unit.
1Junction unit connections checkALL OKPROBLEMS ENCOUNTEREDACTION
Check that the engine management control unit connections are correct by carrying out the testSee Test 1060GN CHECK ON ENGINE MANAGEMENT CONTROL UNIT SENSOR CONNECTIONS 2End of diagnosis