194002896 - Y056 P0697 - SENSOR POWER SUPPLY 3

The diagnostic equipment signals: Error P0697 (Sensor power supply 3).
This error is detected if there is a short circuit to positive (detail "beyond the upper limit") or a short circuit to earth or a brek (detail "below the lower limit") in the circuit connected to Pin 22, or 44 of the junction unit.
1Junction unit connections checkALL OKPROBLEMS ENCOUNTEREDACTION
Check that the engine management control unit connections are correct by carrying out the test    See Test 1060GP CHECK ON ENGINE MANAGEMENT CONTROL UNIT SENSOR CONNECTIONS 3End of diagnosis