194004757 - 5580EB SIREN OPERATION CHECK

CHECK TO BE PERFORMEDRESOLUTION IF THE CHECK IS NOT OK
1Connect the diagnostic instrument in Voltmeter mode with the positive terminal on Pin 1 and the negative earthed to Pin 3 of the alarm siren    See P090 ALARM SIRENThe direct voltage reading should be 12 Volt.Restore the connections between the Body Computer node, siren and earth    See E7015 ALARM
2Disconnect the siren connectora Body Computer connector B and check the continuity of the wiring between Pin 2 of the siren connector and Pin 25 of Body Computer connector B    See P090 ALARM SIREN    See M001 BODY COMPUTERRestore wiring continuity    See E7015 ALARM
3Check the insulation of the earth line    See E7015 ALARMRestore wiring insulation
4Replace the siren    Op. 5580E40 ANTI-THEFT DEVICE SIREN - R+R
- Siren
- Siren pinout1. Power supply2. Serial line3. Earth4. N.C.