194000610 - 5040B14 AIR CONDITIONING SYSTEM MULTISTAGE PRESSURE SWITCH - R+R

Removing ( Refitting )
Follow the safety instructions    Op. 5040 AIR CONDITIONING CASING AND COMPONENTS
- Turn the ignition key to the OFF position.- Disconnect the negative battery terminal.
DescriptionConnector
BATTERY    See A001 BATTERY
    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE    Op. 1048A10 AIR FILTER ASSEMBLY - R.R.1. Release it from the mounting and disconnect the electrical connection (1a) from the air conditioning system multistage pressure switch (1b).Undo the air conditioning system multi-stage pressure switch and remove it from the pipe.
DescriptionConnector
1aLINEAR SENSOR FOR FANS    See K120 LINEAR SENSOR FOR FANS
Refitting ( Removing ) - Check that the air conditioning system linear pressure sensor is not damaged.- Tighten the air conditioning system linear pressure sensor to the pipe.- Connect the electrical connection for the linear pressure sensor.
DescriptionConnector
LINEAR SENSOR FOR FANS    See K120 LINEAR SENSOR FOR FANS
    Op. 1048A10 AIR FILTER ASSEMBLY - R.R.    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE- Connect the negative battery terminal.
DescriptionConnector
BATTERY    See A001 BATTERY