194000629 - 5040D57 <x>AIR CONDITIONER AIR DISTRIBUTION LEFT FLAP DRIVE MOTOR - R&R WITH DASHBOARD CROSS MEMBER REMOVED</x>

Removing ( Refitting ) 1. Release the electrical connection (1a) for the distribution flap control motor (1b) and disconnect it.2. Undo the two fixing bolts and remove the motor from the air conditioning casing.
DescriptionConnector
1aLEFT AIR DISTRIBUTION ACTUATOR    See N113 LEFT AIR DISTRIBUTION ACTUATOR
Refitting ( Removing ) - Check that the control motor for the left upper air distribution flap for the air conditioning is not damaged.- Place the air distribution flap control motor in position.- Tighten the two bolts fixing the distribution flap control motor to the air conditioning casing and secure it.- Connect the electrical connection to the distribution flap control motor.
DescriptionConnector
LEFT AIR DISTRIBUTION ACTUATOR    See N113 LEFT AIR DISTRIBUTION ACTUATOR
Carry out the actuator vane position self-learning procedure using the Examiner.