194000630 - 5040D59 AIR CONDITIONER MIXER LEFT FLAP MOTOR - R R WITH INSTRUMENT PANEL CROSS MEMBER TAKEN OFF

Removing ( Refitting ) 1. Release the electrical connection (1a) for the mixture flap control motor (1b) and disconnect it.2. Release the flap operating lever carefully.3. Undo the two fixing bolts and remove the motor from the air conditioning casing.
DescriptionConnector
1a)MIXTURE FLAP ACTUATOR    See N081 MIXTURE FLAP ACTUATOR
Refitting ( Removing ) - Check that the control motor for the air conditioning mixture flap is not damaged.- Place the air mixture flap control motor in position.- Tighten the two bolts fixing the air mixture flap control motor to the air conditioning casing and secure it.- Attach the flap operating lever carefully.- Connect the electrical connection to the mixture flap control motor.
DescriptionConnector
MIXTURE FLAP ACTUATOR    See N081 MIXTURE FLAP ACTUATOR
Carry out the actuator vane position self-learning procedure using the Examiner.