194000635 - 5040D84 AIR CONDITIONING LEFT AIR MIXTURE FLAP CONTROL MOTOR - R.R

Removing ( Refitting ) - Turn the ignition key to the OFF position and extract it.- Disconnect the negative battery terminal.
DescriptionConnector
BATTERY    See A001 BATTERY
- Working from inside the vehicle, carry out the following operations:(Left side)    Op. 7040A65 CONSOLE SIDE CLOSING (ONE) - R.R.(Left side)    Op. 5010B24 UNDER-FACIA AIR DUCTS - R.R.1. Release the electrical connection (1a) for the mixture flap control motor (1b) and disconnect it.2. Release the flap operating lever carefully.3. Undo the two fixing bolts and remove the motor from the air conditioning casing.
DescriptionConnector
1aLEFT AIR MIXTURE FLAP ACTUATOR    See N078 LEFT MIXED AIR FLAP ACTUATOR
Refitting ( Removing ) - Check that the control motor for the air conditioning mixture flap is not damaged.- Place the air mixture flap control motor in position.- Tighten the two bolts fixing the air mixture flap control motor to the air conditioning casing and secure it.- Attach the flap operating lever carefully.- Connect the electrical connection to the mixture flap control motor.
DescriptionConnector
LEFT AIR MIXTURE FLAP ACTUATOR    See N078 LEFT MIXED AIR FLAP ACTUATOR
(Left side)    Op. 5010B24 UNDER-FACIA AIR DUCTS - R.R.(Left side)    Op. 7040A65 CONSOLE SIDE CLOSING (ONE) - R.R.- Connect the negative battery terminal.
DescriptionConnector
BATTERY    See A001 BATTERY
Carry out the actuator vane position self-learning procedure using the Examiner.
- Check that the air conditioning is working properly.