194001932 - 5020M30 PUMP FOR METERING FUEL TO SUPPLEMENTARY INDEPENDENT HEATER R R
|  | Open the fuel filler access flap and undo the cap to compensate for the difference in pressure inside the tank. | 
 Removing
		(
		Refitting
Removing
		(
		Refitting )
	- Turn the ignition key to the OFF position.- Disconnect the negative battery terminal.
		)
	- Turn the ignition key to the OFF position.- Disconnect the negative battery terminal.| description | Connector | |
|---|---|---|
| BATTERY | See A001 BATTERY | 


|  | It is advisable to fit a sensor cable to the disconnected pipe to facilitate the subsequent refitting. | 

| Description | Connector | |
|---|---|---|
| 1 | ADDITIONAL HEATER PUMP | See N044 ADDITIONAL HEATER ELECTRIC PUMP | 



 Refitting
		(
		Removing
Refitting
		(
		Removing )
	- Using the sensor cable, fitted previously, position the supply pipe on the fuel tank and connect the rapid connector to the pump.- Attach the supply pipe from the tank to the mountings.- Raise the tank and tighten the mounting bracket front fixing bolts.- Remove the hydraulic column lift.- Connect the connectors for the additional heater supply and return pipes.- Place the fuel pump in position and tighten the fixing nut.- Attach the fuel supply pipes to the additional heater and the return pipes to the tank to the mountings.- Connect the electrical connection to the fuel pump.
		)
	- Using the sensor cable, fitted previously, position the supply pipe on the fuel tank and connect the rapid connector to the pump.- Attach the supply pipe from the tank to the mountings.- Raise the tank and tighten the mounting bracket front fixing bolts.- Remove the hydraulic column lift.- Connect the connectors for the additional heater supply and return pipes.- Place the fuel pump in position and tighten the fixing nut.- Attach the fuel supply pipes to the additional heater and the return pipes to the tank to the mountings.- Connect the electrical connection to the fuel pump.| Description | Connector | |
|---|---|---|
| ADDITIONAL HEATER PUMP | See N044 ADDITIONAL HEATER ELECTRIC PUMP | 
| Description | Connector | |
|---|---|---|
| BATTERY | See A001 BATTERY |