194000221 - 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE
Follow the safety instructions Op. 5040 AIR CONDITIONING CASING AND COMPONENTS1. Use the special draining and repressurizing equipment.
|  | To improve safety the rapid connectors for the equipment connecting pipes have different diameters and are different colours:- larger and blue in colour for the low pressure side;- smaller and red in colour for the high pressure side. | 


|  | The fluid is extremely hygroscopic: avoid leaving the containers open.Refill the system with exactly the same amount of fluid indicated on the container. | 
| Component | Type | Description | Classification | Qty. | Validity | 
|---|---|---|---|---|---|
| Air conditioning circuit | Oil (cm³) | SP 10 | - | 120 ± 15135 ± 15 | 2.2 petrol1.9 jtd2.4 jtd | 
|  | If there are accidental breaks that cause the "rapid" draining of the system (in less than 5 minutes) then the exact amount of fluid that comes out cannot be determined because the high pressure may cause seepage.Add the following recommended amount of oil 50 cm3. | 
| Component | Type | Description | Classification | Qty. | Validity | 
|---|---|---|---|---|---|
| Air conditioning circuit | Refrigerant fluid [cm³] | R134a | - | 730 ± 40 | 
|  | Use filtered air to prevent the introduction of foreign bodies into the system. | 
|  | If the system is WASHED the entire amount of compressor oil in the system will be removed. | 
| Component | Type | Description | Classification | Qty. | Validity | 
|---|---|---|---|---|---|
| Air conditioning circuit | Oil (cm³) | SP 10 | - | 120 ± 15135 ± 15 | 2.2 petrol1.9 jtd2.4 jtd |