|  | PRELIMINARY CHECKS | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
| 0 | Having carried out the road test, during the    See table S015 VEHICLE RUNNING NOISEthere was a noise from the front identified as a noise coming from the passenger compartment fan. | Move on to Step 1 |  |  | 
|  | FAN CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
| 1 | Check the climate control fan.In particular, check: that the fan and spiral is clean, if there are any foreign bodies, deposits of dust on the vanes and/or leaves remove them/blow through moving the fan from the engine support;that there are no breaks or cracks in the fan;there are no vibrations or noise at low speed (check the operation with the fan detached from the assembly but the electrical connection fitted).
 |  | "The operation for determining vibrations should be carried out with great care wearing protective goggles to avoid fragments of the fan being expelled into the surrounding area" | 
 | Move on to Step 2 | 1.Fan dirty | 1.Clean the fan casing and all the ducts. | 
| 2.Presence of breaks or cracks in the fan. | 2.Replace the fan.    Op. 5040C30 AIR CONDITIONING FAN - R.R. | 
| 3. Electric motor noisy, fan not balanced or blades. | 3. Replace the fan.    Op. 5040C30 AIR CONDITIONING FAN - R.R. | 
|  | AIR DUCT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
| 2 | Check for foreign bodies and damaged components inside the air ducts. | Move on to Step 3 | Presence of foreign bodies or damaged components inside the air ducts. | Eliminate the obstructions from the dashboard ducts. | 
|  | AIR VENT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
| 3 | Check that the vents are intact and that there are no foreign bodies that could give rise to noise. | Move on to Step 4 | Vents obstructed. | Restore the operation of the vents. | 
|  | POLLEN FILTER CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
| 4 | Check that the pollen filter is not blocked and that the recirculation air intake is not blocked with foreign bodies or parts (e.g. wiring) that are not correctly fitted. | Move on to Step 5 | 1. Filter obstructed. | 1. Replace the filter element    Op. 5010B08 CLIMATE CONTROL OUTSIDE AIR PURIFYING (POLLEN) FILTER - R.R. | 
| 2. Air intake blocked by foreign bodies. | 2. Eliminate the obstructions and restore correct operation. | 
|  | FAN INTAKE CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
| 5 | Check that the fan intake in the air intake chamber is not blocked by the presence of foreign bodies. | End of diagnosis | Presence of foreign bodies in the air intake chamber. | Eliminate the obstructions and restore correct operation. |