194002906 - Y066 P2008 - FLOW BYPASS VALVE (SC TO EARTH)

The diagnostic equipment signals: Error P2008 (flow valve), with detail "short circuit to earth"
This error is detected if there is a short circuit to earth in the circuit connected to Pin 45 of the junction unit for at least 0.24 secs.
0Preliminary checksALL OKPROBLEMS ENCOUNTEREDACTION
In the junction unit under the dashboard    See B002 JUNCTION UNIT UNDER DASHBOARDcheck that fuse F35 has not blown (it is the third one from the right in the top row)Move on to Step 1Fuse F35 has blownContinue as indicated in the test    See Test 1064BE SUPERCHARGING VALVE PROTECTIVE FUSE CHECK
1Flow modifying solenoid valve checkALL OKPROBLEMS ENCOUNTEREDACTION
Check that the flow modifying solenoid valve is working properly by carrying out the test    See Test 1060EB CHECK ON OPERATION OF FLOW SOLENOID VALVEEnd of diagnosis