194000904 - 7010C12 <x>REAR SIDE DOOR EXTERIOR HANDLE (ONE), LH OR RH - R&R WITH INTERIOR SUPPORT FRAME REMOVED</x>
Removing ( Refitting ) 1. Lift up the safety tabs (1a) for the plate joining the exterior/interior handle (1b) on both sides and push upwards using the end (1c) of the actual plate to release the pins (1d) securing the exterior handle.
1. Extract the exterior handle turning it upwards.
1. Undo the three bolts fixing the central locking actuator to the door frame.
1. Remove the interior handle (1a) assembly from the central locking actuator (1b).2. Release the end (2a) of the handle and disconnect the connecting rod (2b) from the lever (2c).
Refitting
(
Removing
)
- Connect the connecting rod and secure it to the interior handle.- Place the central locking actuator in position and secure it using the fixing bolts.- Position the interior handle and keep it pressed against the door frame.1. With the help of a second mechanic, fit the exterior handle in place starting from the top part turning it downwards.
1. When the fitting is completed, keep pressing the exterior handle so that the mounting pins are correctly inserted in the interior handle.2. Secure the interior handle to the exterior handle pulling downwards until the end (2a) of the plate (2b) is in the end of travel position.3. Lower the safety tabs on both sides.